Course contents

Unit 8: High availabilityLesson 8.5 (3 of 5 in this unit)46 of 63 in the Advanced Cisco SD-WAN course

Control session outage versus user-plane forwarding

Control down is not forwarding down: what each controller, Manager and edge failure takes away, how three commands show which plane failed, and a worked case of a branch that looked dead.

Advanced · 15 min read

You'll learn to separate the management, control and data planes, say what each kind of failure takes away and what it leaves working, prove which plane failed with three commands, and write an incident note that states what is still forwarding.

Technical definition

A control outage is a loss of the control connections between a WAN Edge and the Controllers, the Validator or the Manager. It stops the flow of routing information, policy and management actions. It does not by itself stop the IPsec tunnels, which are the data plane, so user traffic can keep flowing for a while on what the edge already learned.

Three planes, three different failures

A dashboard that shows a red control connection invites a quick conclusion: the site is down. Often it is not, because three separate planes cooperate in the fabric and each can fail on its own. The management plane configures and watches. The control plane distributes routes, TLOC information, keys and policy. The data plane carries user packets over IPsec tunnels between edges. A fault in one plane has a specific, limited effect on the others.

Diagram
Control plane versus data plane
Control plane versus data plane

The control plane carries routing information, policy and keys between the edge and the Controllers. The data plane carries user packets in IPsec tunnels between edges. The data plane runs on what the control plane delivered earlier, so it can keep working for a while after the control plane stops.

Control planeOMP, keys, policyedge to Controllerslearns what is new
Data planeIPsec and BFDedge to edgecarries user traffic
The data plane lives on state the control plane delivered in the past. That is why forwarding outlasts a control outage, and also why it cannot last forever.
Diagram
The three planes and what depends on each
The three planes and what depends on each
PlaneComponentsWhat it doesIf it stops
ManagementSD-WAN ManagerTemplates, monitoring, software, certificatesNo changes pushed and no dashboards; traffic is unaffected
ControlControllers, Validator, OMP sessionsRoutes, TLOCs, keys, policy, joining the fabricNew routes, policy and joins stop; held state keeps forwarding for a time
DataWAN Edges, IPsec tunnels, BFDForwards user trafficTraffic on that tunnel stops; BFD moves it in seconds
Name the plane before naming the outage. The three have different symptoms and different clocks.

What each failure takes away

The useful question about an outage is what is still working and what has stopped. The answer depends on which component or link failed and on how many edges it affects.

Diagram
Six failures and their effect
Six failures and their effect
FailureStill worksStops or degrades
Manager unreachableControl connections, OMP routes, tunnels, user trafficTemplate pushes, dashboards, software actions
Validator unreachableEdges that are already connected, tunnelsAn edge that restarts or drops its session cannot be introduced to the Controllers
One of two Controllers lostEverything, through the other ControllerRedundancy: a second failure now removes the routing picture
All Controllers unreachable (every edge)Tunnels and learned routes for the holding periodNew routes, policy changes, new sites and key refresh; after the holding period the learned routes are removed
One edge cannot reach the ControllersIts tunnels and learned routes for the holding period; other edges are unaffectedThat edge hears no changes, and a restart does not recover it on its own
One tunnel fails between two edgesOther tunnels and pathsTraffic on that tunnel, which BFD moves within seconds
Holding periods and exactly what is held differ between releases and platforms. Read them on your own devices.
Diagram
One alarm, four scopes
One alarm, four scopes

A control connection alarm can mean a single edge has lost its path, every edge has lost the Controllers, only the Manager is affected, or a tunnel between two edges has failed. The first question is how many sites show the same alarm.

Alarm: control down
  • One edgeits own pathor firewall
  • Every edgeControllers orshared trust
  • Manager onlymanagementplane
  • One tunneldata plane,BFD handles it
Count the sites before choosing a cause. One site points at that site's path. Every site points at what they share.

The clock on a control outage

When an edge loses its Controllers it does not forget what it knows. It marks the learned routes stale and keeps using them while the holding period runs. During that time the tunnels stay up and BFD keeps checking them. The picture slowly ages, because nothing new can arrive, and when the holding period ends the edge removes what it held.

Diagram
A control outage over time
A control outage over time

First the control connections drop. The edge marks the learned routes stale and keeps forwarding. While the holding period runs, new routes and policy changes are not heard. When the holding period ends, the edge removes the held routes and forwarding stops.

  1. Lostcontrolconnections drop
  2. Heldroutes stale,tunnels up
  3. Ageingnew routesnot heard
  4. Expiryheld routesremoved
The holding period is time to repair, not a sign that the fault is minor. Read the timer in your release.

Two consequences matter in an incident. Failures that need new information, such as a new destination or a changed policy, show up early and look partial: some traffic works and some does not. Failures that need the old information to expire show up late and look total: everything stops at once, long after the original fault. A team that stops looking once users report that everything works can be surprised by the second kind.

Diagram
Early and partial, late and total
Early and partial, late and total

A failure that needs new information, such as a new destination or a changed policy, shows up early and looks partial. A failure that needs the held information to expire shows up late and looks total.

Needs new informationNew destination or policyshows early, looks partial
Needs old information to expireHeld routes removedshows late, looks total
Both come from the same control outage, at different times.

The holding period starts with the first failure, not with the first complaint. Where that deadline lands on the calendar matters as much as its length, because an outage that starts late in the working week runs out when few people are watching.

Diagram
When the holding period ends (computed)
When the holding period ends (computed)
CaseOutage startsHolding period (assumed)Held routes removed
The lesson's case, 12-hour timerMon 9 Nov, 08:5512 hoursMon 9 Nov, 20:55, evening
A short timer, 4 hoursMon 9 Nov, 08:554 hoursMon 9 Nov, 12:55, midday
Friday evening, 12 hoursFri 13 Nov, 17:3012 hoursSat 14 Nov, 05:30, weekend night
Friday evening, 24 hoursFri 13 Nov, 17:3024 hoursSat 14 Nov, 17:30, weekend afternoon
Friday evening, 48 hoursFri 13 Nov, 17:3048 hoursSun 15 Nov, 17:30, weekend afternoon
Calculated by script on an example November 2026 calendar. The holding periods are assumptions: 12 hours is a commonly documented default, and the real value and what is held depend on the release and platform.

Prove which plane failed

Three commands on the affected edge answer three separate questions, and the combination tells you the scope. Control connections show the control plane. BFD sessions show the data plane. OMP routes show the routing picture the edge is using right now.

Diagram
Three commands, three planes
Three commands, three planes

Show control connections tells you whether the control plane is up. Show BFD sessions tells you whether the tunnels carry traffic. Show OMP routes tells you which routing picture the edge uses, including routes that are held as stale.

  1. Control connectionsState up is healthyconnect or tear_down means the control plane is broken
  2. BFD sessionsState up means tunnels carry trafficLong uptime shows the tunnels did not move
  3. OMP routesS in the status means a held stale routeA missing prefix means a change was not heard
Healthy control with healthy BFD is normal. Broken control with healthy BFD is the case this lesson is about.

A worked case: the branch that was not down

At 09:10 the operations team opens a ticket: BR-04 is down. The dashboard shows both of its control connections as red and raises an alarm. The branch manager calls to say that most things work, but the new payment server at the data centre cannot be reached. That server network, 192.168.40.0/24, was added yesterday. The site had a firewall change at 08:55. Priya starts on the branch edge.

Example output written for this lesson, simplified; real output has more fields and a different layout
BR-04#show sdwan control connections
PEER TYPE  SYSTEM IP     SITE ID  LOCAL COLOR   STATE    UPTIME
vsmart     10.255.0.11   1        biz-internet  connect  -
vmanage    10.255.0.10   1        biz-internet  connect  -
Both peers are in the connect state with no uptime, so the edge is trying and failing to reach them. The control plane is broken at this site. That alone does not say that forwarding is broken.
Example output written for this lesson, simplified; real output has more fields and a different layout
BR-04#show sdwan bfd sessions | include 10.255.1.1
10.255.1.1   10   up   mpls          mpls          172.16.4.2    172.16.1.1     12346  ipsec  7   1000   9:02:14:51
10.255.1.1   10   up   biz-internet  biz-internet  203.0.113.40  198.51.100.20  12346  ipsec  7   1000   9:02:14:50
Both tunnels to the primary hub are up, and their uptime of more than nine days shows they did not flap during the incident. The data plane is healthy, and user traffic that follows a learned route is being delivered.
Example output written for this lesson, simplified; real output has more fields and a different layout
BR-04#show sdwan omp routes
VPN  PREFIX            FROM PEER    TLOC                      STATUS
10   192.168.10.0/24   10.255.0.11  10.255.1.1 mpls           S,I,R
10   192.168.10.0/24   10.255.0.11  10.255.1.1 biz-internet   S,I,R
The data centre prefix 192.168.10.0/24 is still installed, marked S for stale, which is why that traffic works. The new prefix 192.168.40.0/24 is not in the list at all, because it was advertised after the control connections dropped and BR-04 could not hear it. This explains the partial symptom exactly.
Diagram
Evidence from the case
Evidence from the case

The control connections are in the connect state, so the control plane is broken at this site. The BFD sessions are up with long uptime, so the data plane is healthy. The old prefix is held as stale and works. The new prefix is missing because the edge cannot hear new routes. The firewall change at 08:55 matches the time the connections dropped.

  1. ControlBoth peers in connect, no uptimeBroken at BR-04 only
  2. DataBoth BFD sessions up for nine daysTunnels did not move
  3. RoutesOld prefix held with S, new prefix missingPartial symptom explained
  4. CauseFirewall change at 08:55 matches the dropControl ports blocked from BR-04
Three commands gave three different answers, and together they gave the scope: a control fault at one site with the data plane intact.

Priya asks the site contact to review the 08:55 change. It blocked outbound traffic on the ports that the control connections use on the biz-internet transport. Common defaults are UDP 12346 for DTLS and TCP 23456 for TLS, but extra ports can be in use, so the site reads the actual values for the design. Once the rule is corrected the control connections come up and the edge relearns the routes.

Example output written for this lesson, simplified; real output has more fields and a different layout
BR-04#show sdwan omp routes
VPN  PREFIX            FROM PEER    TLOC                      STATUS
10   192.168.10.0/24   10.255.0.11  10.255.1.1 mpls           C,I,R
10   192.168.10.0/24   10.255.0.11  10.255.1.1 biz-internet   C,I,R
10   192.168.40.0/24   10.255.0.11  10.255.1.1 mpls           C,I,R
10   192.168.40.0/24   10.255.0.11  10.255.1.1 biz-internet   C,I,R
The stale flag is gone from the old routes and the new prefix is present with the normal chosen, installed and resolved status. The payment server is reachable. Add one line to the change process: confirm the control connections before a firewall change at a branch is closed.

Report it with what is still working

An outage report that says only that a site is down sends the wrong people to the wrong place and hides how much time remains. A better note names the failing plane, says what keeps forwarding and for how long, and states what is needed to repair it.

Diagram
Four lines for an incident note
Four lines for an incident note
LineFor BR-04Why it matters
What is failingControl connections to the Controller and Manager since 08:55Names the plane and the start time
What still worksBoth tunnels and the routes learned before 08:55Tells users and managers that most traffic is safe
What changes nextNew destinations stay missing; the held routes expire after the holding periodGives the repair a deadline
What is neededThe site restores the control ports on biz-internetNames the owner and the action
The same four lines work for a Controller, Validator or Manager outage. Only the entries change.
Diagram
Two ways to report the same outage
Two ways to report the same outage

A report that says the site is down hides that most traffic works and that a deadline is running. A report that names the plane, what still works and what changes next lets the right team act and tells users what to expect.

BR-04 is downno plane named,no deadline,no owner
Control down at BR-04tunnels up, old routesheld, deadline known,owner named
The second report costs thirty seconds more and removes a round of questions.

Learn more: Controller Certificate and Trust FailuresOMP Blackholes and TLOC ResolutionControl Connection DiagnosticsController HA and Failure Domains

Test yourself

Predict · scenario 1

The Manager has been unreachable for two days. Users report no problems. What is the most accurate statement?

Predict · scenario 2

An edge shows control connections in the connect state, BFD sessions up for days, and an old prefix marked S. A prefix added yesterday at the data centre is missing. What explains the pattern?

Predict · scenario 3

One of two Controllers fails. Every edge still has a control connection to the other one. What changes?

Predict · scenario 4

You want to know whether tunnels are carrying traffic at an edge whose control connections are down. Which command answers that?

Predict · scenario 5

Users report that everything works while the control outage is still unresolved. Why is it wrong to stop looking?

Predict · scenario 6

A control outage starts on Friday at 17:30, and the holding period is 12 hours. When are the held routes removed?

Predict · scenario 7

Which symptom of a control outage shows up late and looks total?

Predict · scenario 8

Five of 40 edges raise the same control connection alarm, and the other 35 are healthy. What is the first question?

FAQ

Do users notice when control connections drop?
Usually not at first. Existing tunnels keep carrying traffic and the edge keeps the routes it learned. The first effects are indirect: a new destination cannot be reached, a policy change does not arrive, or a replaced edge cannot join.
Why can a branch reach old destinations but not a new one?
Old destinations are in the routes the edge learned before the outage and is still holding. A new destination was advertised after the outage began, and an edge with no control connection cannot hear it.
Does losing the Manager stop traffic?
No. The Manager is the management plane: templates, software actions and dashboards. Control connections between edges and Controllers, and the tunnels between edges, do not depend on it for forwarding. The cost is that you cannot push changes or watch the dashboards.
How long does an edge keep forwarding without Controllers?
For a holding period set by the OMP graceful restart timer. Many releases document a default of 12 hours, but the value and exactly what is held differ between releases and platforms, so read it on your devices. Treat it as the time you have to fix the fault.