Unit 8: High availabilityLesson 8.1 (1 of 4 in this unit)18 of 25 in the Advanced Cisco SD-WAN course

Controller HA and failure domains

How Catalyst SD-WAN stays up: Manager clusters and disaster recovery, redundant Controllers and Validators, edge and transport redundancy, and what each failure takes away.

Advanced · 14 min read

You'll learn to say what stops and what keeps working when each Catalyst SD-WAN component or link fails, and place and check the components so that no single failure removes more than it has to.

Technical definition

Failure domain is the set of things that stop working together when one component, link, site or data centre fails. In SD-WAN design the aim is to keep each failure domain small, and to know exactly what it contains before something breaks.

One question per failure

Every redundancy decision in Catalyst SD-WAN answers the same question: if this fails, what stops, and what carries on? The fabric is built from separate planes, so the answers differ a great deal. The management plane (the SD-WAN Manager, formerly vManage) can be down while every packet is still forwarded. The control plane (the SD-WAN Controllers, formerly vSmart) can be down for hours with only a slow loss of function. The data plane (the WAN Edge routers, formerly cEdge or vEdge, and their tunnels) is where a failure is felt by users at once.

The components, what each failure removes

The components, what each failure removes
The components, what each failure removesComponent; What it does; What stops if it fails; How to protect it. SD-WAN Manager (vManage): Configuration, templates, monitoring, software upgrades No configuration changes, no monitoring or alarms. Forwarding is unaffected A cluster (typically three nodes) in one site, and a standby cluster at another site for disaster recovery SD-WAN Controller (vSmart): Distributes routes, TLOCs, keys and policy over OMP No new routes, no policy updates. Edges keep what they have for a graceful-restart period Two or more, in different data centres or cloud zones SD-WAN Validator (vBond): Authenticates devices and tells them where the Manager and Controllers are New devices cannot join. Devices that need to reconnect may fail to More than one, reached through a DNS name that returns several addresses WAN Edge router: Carries the site's traffic into the tunnels The whole site, unless a second edge exists Two edges at the site with a shared LAN gateway Transport (one colour): Underlay path for tunnels Tunnels on that colour. Traffic moves to another colour if one exists Two or more colours, such as MPLS and internetComponentWhat it doesWhat stops if it failsHow to protect itSD-WAN Manager(vManage)Configuration, templates,monitoring, softwareupgradesNo configuration changes,no monitoring or alarms.Forwarding is unaffectedA cluster (typicallythree nodes) in one site,and a standby cluster atanother site for disasterrecoverySD-WAN Controller(vSmart)Distributes routes,TLOCs, keys and policyover OMPNo new routes, no policyupdates. Edges keep whatthey have for agraceful-restart periodTwo or more, in differentdata centres or cloudzonesSD-WAN Validator(vBond)Authenticates devices andtells them where theManager and ControllersareNew devices cannot join.Devices that need toreconnect may fail toMore than one, reachedthrough a DNS name thatreturns several addressesWAN Edge routerCarries the site'straffic into the tunnelsThe whole site, unless asecond edge existsTwo edges at the sitewith a shared LAN gatewayTransport (onecolour)Underlay path for tunnelsTunnels on that colour.Traffic moves to anothercolour if one existsTwo or more colours, suchas MPLS and internet

On small screens, swipe sideways or focus the diagram and use the arrow keys.

Read each row across: the left box names the item, the others describe it.

The rest of the lesson takes the rows in order of how often they matter in practice.

Placing SD-WAN components by failure domain
Placing SD-WAN components by failure domainSite A holds an SD-WAN Manager cluster and SD-WAN Controller CTRL-01. Site B holds a standby Manager and a second Controller. Validators are reached by name so that edges can find one. If Site A is lost, the second controller keeps the control plane and the standby Manager can be activated by an administrator. While the Manager is down the network keeps forwarding; what is lost is the ability to see and change it.Site ASite BManager cluster, three nodesactiveCTRL-0110.255.0.11VAL-0110.255.0.12Standby Managerstarted by an administratorCTRL-02second controllerVAL-02second validatorEdges keep forwarding if the Manager is down. They need a controller to learn routes, so keep two apart.

On small screens, swipe sideways or focus the diagram and use the arrow keys.

Put the two controllers in different places and keep a Manager standby at a second site. Check that the edges can reach more than one controller before an outage tests it.

SD-WAN Manager: a cluster, and a second site

A Manager can run as a single node or as a cluster, and a cluster is typically three nodes. A cluster shares the work and survives the loss of a node. It does not survive the loss of the site that holds all of its nodes. For that, a standby Manager or cluster is built at another site, with its data replicated from the active one. If the active site is lost, an administrator starts the switchover. It is not automatic and it takes time, and the devices have to start talking to the standby afterwards. Support, replication behaviour and the exact procedure differ by release, so check your release's disaster recovery guide before writing any promise into a design.

While the Manager is down the network keeps forwarding. What is lost is the ability to see and change it: a failed link may go unreported, and a configuration change cannot be pushed. In practice the Manager is the component people notice first, because it is the one they look at, and the one that matters least for traffic.

SD-WAN Controllers: two, in different places

Each WAN Edge keeps control connections to a limited number of Controllers. On many releases that number is two, so with two or more Controllers deployed, losing one leaves the other. Spread the Controllers across data centres or cloud availability zones, so one power or network failure does not take all of them. A Controller group (affinity) setting lets you decide which Controllers a given set of edges prefers, which also spreads the load across them. Check the figures for your release.

If every Controller is unreachable, the edges do not stop. They keep the routes, TLOCs, keys and policy they hold, and they keep forwarding. They hold them for a graceful-restart period after the control connection is lost. On current releases this is long, commonly given as 12 hours, but treat that as a figure to check on your release. A short Controller outage is therefore survivable. What it cannot do is react to change: a new site cannot learn routes, a withdrawn prefix is not withdrawn, and a failover that depends on a route update does not happen. Tunnel failure detection still works, because BFD runs between the edges themselves.

SD-WAN Validators: reachable by name

A Validator is the first contact for every device. It checks identity and tells the device which Manager and Controllers to use. Deploy more than one, and configure the edges with a DNS name that resolves to several Validator addresses, so that a device can try the next one. With one Validator down, nothing already connected breaks. A new device cannot join until a Validator answers, and a device that loses its control connections and needs to reconnect may not be able to find a Controller. That is why a Validator outage can look harmless for a day and then matter after a site reboots.

Edge and transport redundancy

At the edge, the failure domain is the router. A branch with one WAN Edge is down when that router is down, however many transports it has. A branch that must survive this has two edges and a shared gateway for the LAN, usually with VRRP. The lab on VRRP and EIGRP on the service side builds this at site 103, where BR-03A and BR-03B serve one site.

Transport redundancy is a separate question. BR-01 has MPLS and internet, so it survives losing either. BR-02 has internet only, so losing it removes the site's WAN even though the router is healthy. Two colours on one router, two routers on one site and two hubs in two data centres each protect against a different failure. A design should say which of the three it is buying.

Does a second internet link count as a second colour?

Not by default. Colour names a transport type, and two links of the same type usually share a colour such as biz-internet. They are still two links, and a failure of one leaves the other, but the policy and tunnel behaviour treat them as the same colour. Whether you name them differently is a design choice. Check how your release handles tunnels to the same colour from two interfaces.

Placing components by failure domain

  • Controllers: at least two, in separate data centres, cloud zones or power and network domains. Two Controllers on the same hypervisor are one failure domain.
  • Validators: more than one, also separated, with a DNS name covering them.
  • Manager: cluster nodes in one site, standby at a second site. A cluster adds capacity and node resilience, not site resilience.
  • Hubs: one per data centre, as in the dual-hub design.
  • Shared dependencies: DNS, NTP and the certificate authority are failure domains too. A Validator that cannot be resolved is as good as down.

A health check you can run

Two commands on a WAN Edge give a quick view of the control plane. Run them in normal operation and keep the output as a baseline, because a baseline makes a later failure obvious.

Example output written for this lesson, simplified; real output has more fields and a different layout
BR-01#show sdwan control connections
PEER    PEER  PEER         SITE  DOMAIN  PEER           PRIVATE        STATE  UPTIME
TYPE    PROT  SYSTEM IP    ID    ID      PRIVATE IP     PORT
vsmart  dtls  10.255.0.11  1     1       192.0.2.11     12346  up     12:05:20:11
vbond   dtls  -            0     0       192.0.2.12     12346  up     12:05:20:30
vmanage dtls  10.255.0.10  1     0       192.0.2.10     12346  up     12:05:19:58
BR-01 has one connection to each kind of component. The Controller (shown here by its older label vsmart) is the one that matters for routes. With a second Controller deployed there would normally be a second vsmart line, and its absence is the first sign that redundancy has been lost without anyone noticing. Site IDs and addresses here are examples.
Example output written for this lesson, simplified; real output has more fields and a different layout
BR-01#show sdwan omp summary
oper-state               UP
admin-state              UP
personality              vedge
omp-uptime               12:05:19:50
routes-received          9
routes-installed         9
routes-sent              2
tlocs-received           7
tlocs-installed          7
tlocs-sent               2
The state and uptime show that the OMP session to the Controller is established and for how long. The route and TLOC counts should match your baseline. A count that drops after a Controller change points at a policy or a missing site. During a Controller outage, the session goes down but the installed routes are normally kept for the graceful-restart period, so forwarding continues.

Outage versus forwarding

When something fails, ask which plane it belongs to. A Manager outage, a Validator outage and a Controller outage leave forwarding alone for a time. A tunnel or edge failure does not. The dual-hub design lesson shows a failover that depends on BFD and so works without any Controller, and one that depends on a route being withdrawn and so does not. Knowing which of your failure cases need the Controller is the same as knowing how long a Controller outage you can survive.

Mistakes that remove the redundancy quietly

  • Two Controllers on the same host or in the same rack, which is one failure domain with two names.
  • A Manager cluster described as disaster recovery, when all three nodes are in one room.
  • A standby Manager that has not been switched to in a test, so its procedure and its effect on the devices are unknown.
  • One Validator address configured on the edges instead of a name, so a single outage blocks reconnecting devices.
  • Redundant components that were healthy at installation and were not checked again.

Test yourself on what each failure removes

Predict · scenario 1

The SD-WAN Manager is down for two hours. What is the effect on branch traffic?

Predict · scenario 2

Both SD-WAN Controllers are unreachable for ten minutes. BR-01 loses its MPLS link during that time and the only route to a data centre prefix was via the MPLS TLOC. What happens?

Predict · scenario 3

A branch router is rebooted during a Validator outage. The Validator is the only one configured by address. What is the likely result?

Predict · scenario 4

Site 103 has two WAN Edge routers sharing one LAN. BR-03A fails. Which statement is correct?

FAQ

If the SD-WAN Controllers go down, does the network stop?
Not at once. WAN Edge routers keep forwarding with the routes and policy they already have, and they keep them for a graceful-restart period after the control connection is lost. That period is long on current releases (check yours), so a short Controller outage is survivable. Changes, new routes and failover that needs a new route wait until the Controllers return.
How many SD-WAN Controllers should a network have?
At least two, in different failure domains such as different data centres or cloud zones. How many control connections each WAN Edge keeps, and how many Controllers a Manager supports, depend on the release and the licence, so check the scale figures for your release.
Is a Manager cluster the same as disaster recovery?
No. A cluster spreads the load and survives the loss of a node inside one site. Disaster recovery is a second, standby Manager (or cluster) at another site, with replicated data. Switching to it is a decision by an administrator and takes time. Check your release's disaster recovery support.