Course contents

Module 4: Device ManagerLesson 4.2 (2 of 3 in this module)7 of 19 in the FortiManager Administration course

Onboard FortiGates to FortiManager: production and lab

Rolling devices under management as a plan: discover, register, model device or device list, pilot and waves, the four gates for each device, and the lab version.

Intermediate · 12 min read

Written for FortiManager 7.6 · FortiManager 7.4: not yet reviewed

Exam domain: NSE 6 FortiManager (7.6) · Device Manager

Before this: Adding FortiGates to FortiManager, Onboard a FortiManager

You'll learn to choose the right way to bring each FortiGate under FortiManager, run the rollout in order for production and for a lab, and say what evidence shows that a device is managed and in step.

From one device to a fleet

Adding one FortiGate is a wizard. Adding a hundred is a plan. The plan has to decide which method fits each group of devices, which devices go first, what is prepared on the FortiGates and on the manager, and what evidence shows each step is finished. Without a plan, the first install is the moment a mistake reaches production.

Diagram
Four ways to bring a FortiGate under management
Four ways to bring a FortiGate under management
MethodStarts fromBest forNeeds
DiscoverFortiManager connects to the FortiGateExisting units that the manager can reachA path from the manager to the unit on TCP 541, and an administrator login on the unit
RegisterThe FortiGate connects to FortiManagerExisting units behind NAT or a firewall that blocks inbound connectionsThe manager address set on the unit, and a path from the unit to the manager
Model deviceAn administrator describes the unit in advanceNew units that do not yet exist at the siteThe serial number and model, and a way for the unit to find the manager
Import a device listAn administrator loads many descriptions at onceA large batch of new units from a purchase listA list in the format the release expects, and the same discovery path as model devices
Names of the wizard choices follow the Add Device wizard on 7.6 and differ between releases.
Diagram
Which method for which devices
Which method for which devices

Existing units that have a configuration are discovered or registered, and then imported. New units that have no configuration are modelled in advance and find their manager by zero-touch provisioning.

Which method
  • Existing, reachablediscover,then import
  • Existing, behind NATregister,then import
  • New unitsmodel device,zero-touch
Existing units need an import. New units need a model.

The production process

Diagram
Production rollout to FortiManager
Production rollout to FortiManager

Prepare the manager and the network, pick a pilot, add and import the pilot, check the evidence, install with a preview, then repeat in waves.

  1. Preparemanager,paths, ADOMs
  2. Pilotone or twounits
  3. Addand import
  4. Checkstatus andpreview
  5. Installwith arollback plan
  6. Wavesrepeat forthe rest
The pilot decides whether the plan works. Every later wave repeats the steps the pilot proved.
Diagram
Production steps and their evidence
Production steps and their evidence
StepWhat you doEvidence
1 PrepareOnboard the manager first, create the ADOMs that match the firmware plan, open TCP 541 where the method needs it, and decide who may authorise devicesThe manager is ready and a test unit can reach it
2 PilotPick one or two units that are not critical and that cover the variety of models and firmware in the estateA short list with the reason for each choice
3 Add and importAdd each unit by the method that fits, then import its policies and objects and settle name conflictsThe unit is in the right ADOM and its policy package matches what is on the device
4 CheckRead the connection, database and configuration status, then compare revisions or open the install preview without installingThe status columns agree, and the preview shows only changes that you expect
5 InstallTake a backup of the FortiGate configuration, install in a change window, and read the install logThe install succeeds, the unit is in sync and traffic is unaffected
6 WavesRepeat in groups, with the lessons from the pilot written into the checklistEach wave finishes with the same evidence as the pilot
Menu names and status words are release dependent. The order and the evidence are what carry over.

The pilot only proves the models it contains. Take an example estate of 100 FortiGates in five models: 3 units of hub model 1, 2 of hub model 2, and 40, 30 and 25 of branch models 1, 2 and 3. One or two units cannot cover five models, so the choice is between a small pilot that leaves models for the next wave to meet first, and a pilot of one unit per model that is still only 5 per cent of the estate.

Diagram
What each pilot covers in an example estate
What each pilot covers in an example estate
Pilot choiceModels coveredUnitsModels first met in a later wave
Ten identical branches1 of 5104
The three units of one hub model1 of 534
One hub and one branch2 of 523
One unit of each model5 of 550
Example estate and example pilots, counted by a short script. If the pilot stays at two units, treat the first unit of each uncovered model in the next wave as its own small pilot.

Install is the step that changes production

Adding and importing change nothing on the FortiGate. The first install can. Read the preview, confirm that the policy package was imported from the device and not created empty, and keep a configuration backup that can be restored from the console.
get system central-management diagnose dvm device list

The first command runs on a FortiGate and shows which manager it points at. The second runs on FortiManager and lists each managed device with its connection, database and configuration status. Together they show whether both sides agree. Output wording differs by release.

The gates for each device

A device is onboarded when it has passed four gates in order. They give a way to explain a stalled device in one sentence, and they match the order of the checks in the troubleshooting lesson.

Diagram
Four gates for a managed device
Four gates for a managed device
GateQuestionEvidence
ReachCan the two sides open the management connection?The connection shows as up
IdentityDoes the manager know which device this is?The serial number matches a device in the right ADOM
ContentDoes the manager hold the device's configuration?The device database is retrieved, and the policy package matches the device
ControlCan the manager change the device safely?The preview is understood, and an install succeeds and leaves the unit in sync
A device that fails an early gate cannot pass a later one. Repair in the same order.
Diagram
Where a device stalls
Where a device stalls

If the connection is down, the problem is reach. If the connection is up but the device is unknown, it is identity. If the device is known but the package does not match, it is content. If an install fails, it is control.

  1. ReachTCP 541, address, FGFM access
  2. IdentitySerial number, ADOM, authorisation
  3. ContentImport done, objects mapped
  4. ControlPreview, install log, rollback
Read the status columns from the left. The first one that is wrong is the layer to fix.

The lab process

In a lab the fleet is two FortiGates, and the same steps apply on a smaller scale. The lab is the place to practise the failures that a production rollout cannot afford.

Diagram
Rollout in production and in a lab
Rollout in production and in a lab
StepProductionLab
PrepareADOM plan, firewall rules for TCP 541, authorisation policyFMG1 at 10.0.1.31 and two lab FortiGates on one management network
PilotOne or two non-critical unitsFGT1 first, then FGT2 once FGT1 is clean
Add and importBy the method each group needsDiscover FGT1, register FGT2 from the unit, so both methods get practice
CheckStatus, revisions, preview, written sign-offStatus and preview, then compare with the course lab's expected output
InstallA change window and a console-ready rollbackA snapshot first, then install, then break something on purpose
WavesGroups by site, model or firmwareNot needed, but the lab can rehearse a failure in the second device
The addresses are the examples used across the course lab and are not real.
Diagram
What a lab practises
What a lab practises

A lab can rehearse a wrong manager address, a blocked port and a wrong ADOM, and can use a snapshot to undo them. A production rollout practises the plan, and cannot afford those errors.

Labwrong addressblocked portundo by snapshot
Productionpilot firstpreview before installbackup ready
Break the lab on purpose, so the production failures look familiar.
7.6
This lesson is written for FortiManager 7.6 and FortiOS 7.6, and the 7.4 differences have not been reviewed. Zero-touch behaviour and the Add Device wizard in particular change between releases.

Rollout faults

Diagram
Faults seen in rollouts
Faults seen in rollouts
What you seeLikely causeFirst check
A device stays Down after it was addedA path change, a firewall timeout, or a wrong manager address on the FortiGateRun get system central-management on the unit, then test the path to the manager
The device appears in the wrong ADOMIt was authorised into the default ADOM or the firmware does not match the intended oneCompare the unit's version with the ADOM version before authorising
The import shows many name conflictsDevices from different sites use the same names for different thingsDecide a naming rule and map per-device values before importing the next unit
The first install removes a policyThe package was created empty and not imported, or the import was partialRead the install preview before accepting it, and import again if needed
A wave fails where the pilot succeededA model or firmware version that the pilot did not coverCompare the failing unit with the pilot units
Devices become out of sync after the rolloutSomeone is changing devices locallyCheck who has access, and apply the workspace and workflow controls
Examples of typical faults. The deeper checks are in the troubleshooting lesson.
Diagram
Fault to first check
Fault to first check

A device that stays down needs the path and the manager address checked. A device in the wrong ADOM needs its firmware compared with the ADOM version. Many name conflicts need a naming rule before the next import. A first install that removes a policy needs the install preview read and the import checked. A wave that fails where the pilot passed needs the failing model compared with the pilot units. Devices out of sync need a check on who changes them locally.

  1. Device stays downPath and manager address on the unit
  2. Wrong ADOMFirmware against the ADOM version
  3. Many name conflictsA naming rule before the next import
  4. Install removes a policyThe preview, and whether it was imported
  5. Wave fails, pilot passedModel or firmware the pilot missed
  6. Devices out of syncWho changes them locally
The colours follow the gates: blue for reach and identity, amber for content, green for control.

Learn more: Adding FortiGates to FortiManagerZero-touch FortiGate onboardingTroubleshooting FortiManager

Test yourself on the rollout

Predict · scenario 1

A branch FortiGate is behind NAT, and the firewall team will not allow inbound TCP 541. It already has a working configuration. Which method fits?

Predict · scenario 2

A device shows the connection as up, but it is not in the ADOM that was planned. Which gate failed?

Predict · scenario 3

Which choice makes the best pilot for an estate of two hub models and three branch models?

Predict · scenario 4

After a successful add and import, what must happen before the first install?

Predict · scenario 5

An estate has five models. A pilot of one hub and one branch, of different models, covers how many models, and how many are first met in a later wave?

Predict · scenario 6

On a FortiGate, which command from this lesson shows the manager the unit points at?

Predict · scenario 7

A device is up and in the right ADOM, but the policy package does not match what is on the device. Which gate has not passed?

Further reading in Fortinet's documentation

Links open the named page in Fortinet's documentation (checked 19 October 2026). RouteLearn is an independent educational resource, not affiliated with or endorsed by Fortinet. Fortinet, FortiGate, FortiOS, FortiManager and FortiGuard are trademarks of Fortinet, Inc. Example output on this page is illustrative.

FAQ

How is this different from the Adding FortiGates lesson?
That lesson explains the wizard for one device: discover or register, import, and the checks. This lesson is about the whole rollout: which method suits which group of devices, how to order the waves, what to prepare on each side, how to prove a device is managed, and how the lab version differs. Read the wizard lesson for the screens and this one for the plan.
Which method should be used for an estate of existing FortiGates?
Existing units already carry a configuration, so the choice is between discovery from FortiManager when it can reach them, and registration from the FortiGate when it cannot. Both then import the existing policies before any install. Model devices and zero-touch provisioning suit new units that do not have a configuration yet.
How many devices should the first wave have?
Few enough that a mistake is cheap and informative: one or two non-critical units that cover the variety in the estate, such as one hub model and one branch model. A pilot that is too uniform can hide a problem that appears on the next model or firmware version.
What does a managed device look like in the status columns?
The connection is up, the device database has been retrieved, and the configuration status says the FortiGate and FortiManager agree. The words and columns differ by release, so use the device status lesson as the reference for yours, and treat a device as onboarded only when all three agree and a first install has been previewed.
Can a lab skip the import step?
Only when the lab unit has no configuration worth keeping, such as a freshly deployed virtual machine. A lab unit that has policies from an earlier exercise should still be imported, because the import is part of what the lab is practising.