Start from the question, not the chart
The Manager (formerly vManage) collects a lot of data, and it is easy to look at the wrong chart. A dashboard is best used by asking a short sequence of questions. Is the control plane healthy? Which sites are not healthy? What is wrong at that site? Which tunnel or application shows it? Each question maps to a panel or page.
Overview to site to device to tunnel to CLI.
- Overviewcontrol, sites
- Sitehealth, tunnels
- Deviceinterfaces,CPU
- Tunnelloss, latency
- CLIthe proof
Is the control plane healthy, which sites are unhealthy, what is wrong at that site, and which tunnel or application shows it. Each question points to a different panel.
- Controlare controllersand edges up?
- Siteswhich sitesare unhealthy?
- Site detailwhat is wrongthere?
- Tunnel or appwhere doesit show?
What the overview answers
| Panel (typical name) | Question it answers | Next click |
|---|---|---|
| Control status | Are controllers and edges connected? | The device list, filtered by state |
| Site health | Which sites have poor tunnels or applications? | The site page |
| Transport health | Is a transport losing packets or adding delay across sites? | Tunnels, filtered by colour |
| Top applications | What is using the WAN? | Application page, then QoS counters |
| Alarms and events | What changed and when? | The alarm detail, then the device |
| Certificate or licence status | Is something about to expire? | Certificate or licence page |
Health colours summarise a measurement against a threshold. A site shown as poor usually means that measured loss, latency or jitter crossed a limit on its tunnels, not that the site is down. The meaning and the limits are release and configuration dependent, so check them before relying on a colour.
A poor health colour means measured loss, latency or jitter crossed a limit on the site's tunnels. A site that is down is out of contact and shows as disconnected, with no recent data at all.
A control connection alarm sends the first check to the control connections from the device itself. A BFD alarm points at the BFD sessions and the transport behind the tunnel. An interface alarm points at the link and the provider handoff. An expiry alarm points at the date on the certificate or licence page.
- Control downcontrol connectionsfrom the device
- BFD downBFD sessions andthe transport
- Interface downlink and providerhandoff
- Expiringthe date on thecertificate page
| Alarm type | What it suggests | First check |
|---|---|---|
| Control connection down | The device lost contact with a controller | Control connections, from the device itself |
| BFD session down | A tunnel to another edge is gone | BFD sessions and the transport behind that tunnel |
| Interface down | A local link failed | Interface status and the cable or provider handoff |
| Certificate or licence expiring | A trust or licence deadline is near | The certificate or licence page, with the date |
From site to tunnel
On a site or device page, the Manager lists interfaces, tunnels, control connections and applications. A tunnel page shows loss, latency and jitter over time between two edges, by colour. The pattern in the graph is a clue: a flat loss of a few percent suggests a bad circuit, a sawtooth suggests a congested one, and a sudden stop suggests a device or path failure.
Shape of the line points to a cause.
- Steady loss of a few percentFaulty circuit or duplex mismatchCheck interface errors
- Rising and falling with the dayCongestion at busy timesCheck QoS and shaping
- Drops to zero and staysPath or device failureCheck control and BFD state
A worked case: all green, and the video calls stutter
Users at the branch BR-05 report that video calls to the hub have stuttered since 09:00. The overview is green and the site health for BR-05 is good. The overview summarises across sites and over time, so a problem on one tunnel can be hidden in it. The tunnel pages for BR-05 are the next step, and the graph for biz-internet shows a flat line of about 5 percent loss since 09:00 while mpls shows none. The device confirms the numbers.
BR-05#show sdwan app-route stats TUNNEL (remote) LOSS LATENCY JITTER mpls to HUB-01 mpls 0 45 6 biz-internet to HUB-01 biz-inet 5 62 12
BR-05#show interface GigabitEthernet2 GigabitEthernet2 is up, line protocol is up 5 minute input rate 4500000 bits/sec 183044 input errors, 183044 CRC, 0 frame, 0 overrun, 0 ignored
The overview is green, but the tunnel graph for biz-internet shows a flat five percent loss since nine o'clock. The device confirms the loss, and the interface shows a large count of CRC errors.
- OverviewAll greenAveraged across sites and time
- Tunnel graphbiz-internet: flat 5 percent lossSince 09:00, mpls clean
- Deviceapp-route stats: loss 5Above the video limit of 3
- InterfaceLarge count of CRC errorsPhysical link or handoff
The repair is outside the Manager: change the cable or the port, or ask the provider to check the handoff, then watch the loss on the tunnel graph and in show sdwan app-route stats fall back to zero. Allow for the averaging window before the graph and the class eligibility settle. The Manager cannot fix the fault, and it may not have raised an alarm, because nothing went down.
Why was the overview green? Every summary averages, and an average pulls one bad tunnel toward the good ones around it. The more that is averaged, the smaller the same fault looks.
| What is shown | What is averaged | Loss shown | Against the 3 percent video limit |
|---|---|---|---|
| Tunnel graph, biz-internet, now | That tunnel only | 5 percent | Over the limit |
| BR-05 site, both transports | 2 tunnels, one clean | 2.5 percent | Under the limit |
| BR-05 over 24 hours at 15:00 | Bad for 6 hours of 24 | 1.25 percent | Under the limit |
| All 20 sites, two transports each | 40 tunnels, one bad | 0.125 percent | Under the limit |
| Question | Best source | Why |
|---|---|---|
| Which site or transport looks unhealthy | Dashboard | It summarises many devices at once |
| Is the loss steady or does it follow the day | Tunnel graph | It shows the shape over time |
| What is the value now, on this device | CLI | It is the reference and is not averaged for display |
| Why are frames lost on a link | CLI interface counters | Errors and drops are counted per interface |
When the dashboard is wrong or old
Fresh against stale data.
- All green while users complain: the dashboard averages over time and sites. Check the application and tunnel pages for the affected pair.
- A device with no recent data: confirm the control connection from the device side before assuming the site is down.
- An alarm that clears itself: note the time and look at the device logs; intermittent faults are easy to lose.
- Alarms can be sent to syslog or SNMP tools, so the network team sees them without opening the Manager.
Learn more: WAN Edge Show Commands and InterpretationOMP and BFD Fault Isolation
Test yourself
Site health for BR-02 is poor. What does that most likely tell you?
A branch's charts stopped updating at 14:10. What do you check first?
The overview is green but users at one branch complain about video. What is the best next step?
A tunnel shows a flat 5 percent loss that does not follow the time of day, and the interface shows many CRC errors. Where is the fault?
Loss on a tunnel is steady at 3 percent all day. Which cause fits best?
BR-05 has two tunnels, one with 5 percent loss and one with none. If its site health is the plain average of the two against a 3 percent limit, what does the site show?
Which source gives the reference value on this device right now?
An interface-down alarm appears for a branch. What is the first check?