Newer path optimization features and version gating

How Enhanced Application-Aware Routing measures paths with data packets, what its three timer modes and the dampening window mean in minutes, which releases and mixed-version rules apply, and how to check which measurement a tunnel uses.

Advanced · 21 min read

You'll learn to explain how Enhanced Application-Aware Routing differs from the classic timers, read the three timer modes and the dampening window, calculate how fast each mode reacts to a steady loss, and describe the release and mixed-version rules before enabling it.

Technical definition

Enhanced Application-Aware Routing (EAAR) is a Cisco Catalyst SD-WAN capability, listed for IOS XE Catalyst SD-WAN Release 17.12.1a and Manager Release 20.12.1 and later, that measures loss, latency and jitter with data packets and uses shorter timers, so that a tunnel that misses its SLA class can be left sooner than with the classic timers. It has to be enabled on both ends of a tunnel.

Why the classic timers feel slow

Classic application-aware routing probes every tunnel with BFD hello packets and averages the results over long intervals. With the defaults printed in the Cisco chapter, one poll interval is 10 minutes and the edge keeps 6 of them, so a steady fault that is only just over a limit can take an hour to move traffic. That is a sound design for a stable link and a poor one for a voice call that sours in the next minute. EAAR was added to shorten the loop.

Diagram
Classic timers against EAAR
Classic timers against EAAR

Classic application-aware routing samples with BFD hello packets and averages over long intervals. Enhanced application-aware routing measures with data packets and uses shorter intervals.

Classic AARBFD hello probes10 minute polls
EAARdata packets measured10 second polls
Same SLA class and the same policy; the measurement and the clock change.
Diagram
Classic timers at their defaults
Classic timers at their defaults
SettingDefaultCommand printed in the chapter
Hello interval of the BFD probe on each tunnel1 secondbfd color interval
Poll interval, the length of one averaging bucket10 minutesbfd app-route poll-interval
Multiplier, the number of buckets kept6bfd app-route multiplier
Length of the full window (computed: 6 x 10 minutes)60 minutesResult of the two settings above
Hello packets per poll interval (computed: 600 seconds at 1 per second)600 packetsResult of the first two settings
Defaults from the Cisco Catalyst SD-WAN Policies Configuration Guide for IOS XE Catalyst SD-WAN Release 17.x, application-aware routing chapter, updated December 2025. The chapter was read only in part, and other releases and platforms can differ. The two computed rows are arithmetic on the printed defaults.

What EAAR measures differently

The classic measurement is a sample: a small probe goes through the tunnel and the edge infers the quality of everything else from it. EAAR measures the traffic itself. The Cisco community note describes loss counted per queue from sequence numbers, with the receiving edge reporting it back through BFD, and a small amount of metadata added to each packet. These details come from a community note and a blog, not from the Cisco chapter, so they are an indication of the design rather than a specification.

Diagram
How an enhanced measurement flows
How an enhanced measurement flows

Sender adds metadata to data packets. The receiver counts what arrived against the sequence numbers. The receiver reports the result back through BFD. The sender compares the values with the SLA class and decides.

  1. Senddata packets carrya little metadata
  2. Countreceiver comparesarrivals with numbers
  3. Reportresult returnsthrough BFD
  4. Decidecompare with theSLA class
Sequence from a Cisco Community note; per-queue loss applies to IPsec tunnels only.
Diagram
Classic measurement against enhanced measurement
Classic measurement against enhanced measurement
AspectClassic AAREAAR
What carries the measurementBFD hello probes sent on each tunnel (Cisco AAR deployment guide, 2020)Actual data packets, with BFD used for reporting (community note)
LossPer tunnel, a percentage from 0 to 100 (deployment guide)Per queue on IPsec tunnels; no per-queue measurement on GRE tunnels (community note; the Cisco chapter lists the GRE restriction)
Local lossNot described in the notes readLocal queue loss and WAN loss are both counted by default; a command to ignore local loss exists (Cisco chapter, summarised)
Per-class measurementPer-class AAR with an app probe class, listed from 17.4.1a and 20.4.1With an app probe class, only that queue is used for that SLA class; without one, all queues are accumulated (community note)
CostProbe traffic onlyAbout 12 bytes of metadata per packet, and the tunnel MTU adjusts (blog); no change to tunnel scale (blog)
Mixed sources, labelled in the cells. The Cisco AAR deployment guide dates from 2020 and does not mention EAAR. The community note and the blog are not Cisco documentation, and their figures are not confirmed by the Cisco chapter.

Three timer modes

The Cisco chapter packages the timers as three modes. Each is a poll interval and a multiplier, and the window over which a decision is made follows from them. The modes trade speed for stability: a short window reacts fast and also reacts to noise, and a long window is calm and slow.

Diagram
Aggressive, moderate and conservative
Aggressive, moderate and conservative

Aggressive uses a ten second poll interval and a multiplier of six. Moderate uses sixty seconds and five. Conservative uses three hundred seconds and six.

EAAR modes
  • Aggressive10 s poll,multiplier 6
  • Moderate60 s poll,multiplier 5
  • Conservative300 s poll,multiplier 6
Values as printed in the Cisco chapter's mode table.
Diagram
Mode values printed in the Cisco chapter
Mode values printed in the Cisco chapter
SettingAggressiveModerateConservative
EAAR poll interval10 seconds60 seconds300 seconds
EAAR poll multiplier656
EAAR poll window10 s to 60 s60 s to 300 s300 s to 1,800 s
SLA dampening multiplier1204012
SLA dampening window20 minutes40 minutes60 minutes
From the Cisco chapter on enhanced application-aware routing, updated December 2025, as read. The chapter says the mode values are set only through a CLI template, not through feature templates (summarised). The upper end of each poll window equals the interval multiplied by the multiplier: 10 x 6, 60 x 5 and 300 x 6.

A simple model shows what the modes mean for a steady fault. Take the same model as the brownout lesson: a voice limit of 2 percent loss, a loss that starts at the beginning of an interval and stays level, and a decision when the average over the window first exceeds the limit. The real mechanism may differ in detail, so the figures are an upper bound for a steady fault and a guide to the order of magnitude.

Diagram
Time until the average passes a 2 percent limit (computed)
Time until the average passes a 2 percent limit (computed)
Sustained lossAggressive, 10 s x 6Moderate, 60 s x 5Conservative, 300 s x 6Classic default, 600 s x 6
2.4 percent, just over the limit6 intervals, 60 seconds5 intervals, 5 minutes6 intervals, 30 minutes6 intervals, 60 minutes
5 percent3 intervals, 30 seconds3 intervals, 3 minutes3 intervals, 15 minutes3 intervals, 30 minutes
10 percent2 intervals, 20 seconds2 intervals, 2 minutes2 intervals, 10 minutes2 intervals, 20 minutes
25 percent1 interval, 10 seconds1 interval, 1 minute1 interval, 5 minutes1 interval, 10 minutes
Computed by script. The edge is assumed to compare the average over the full window with the limit after each completed interval, as in the brownout lesson. A real edge may also use the interval in progress. The Cisco chapter prints convergence windows of 10 to 60 seconds, 60 to 300 seconds and 300 to 1,800 seconds for the three modes, which this model matches at both ends.

SLA dampening

A fast decision creates a new risk: a path whose quality hovers around the limit could pull traffic away, take it back and pull it away again. EAAR comes with an SLA dampening setting, and its name and long windows point at this kind of flapping. The Cisco chapter gives a multiplier and a window for each mode, and a blog states that the multiplier is applied to the EAAR poll interval. The pages read do not spell out the exact rule that dampening applies, so this lesson states the arithmetic and leaves the behavior to the Cisco chapter and a lab test.

Diagram
Two windows on the same poll interval
Two windows on the same poll interval

Detection runs on the poll window, which is seconds or minutes. The dampening window in the Cisco table is much longer, twenty to sixty minutes. Both are built from the poll interval, and the pages read do not state the rule that dampening applies.

  1. Detection window10 s to 30 minutes,set by the mode
  2. Dampening window20 to 60 minutes,set by the mode
  3. Poll intervalthe unit that bothwindows are built on
Window lengths from the Cisco table; the exact dampening rule is not in the pages read.
Diagram
Dampening window from the multiplier (computed)
Dampening window from the multiplier (computed)
ModeMultiplier x poll intervalResultWindow printed by Cisco
Aggressive120 x 10 seconds1,200 seconds, 20 minutes20 minutes
Moderate40 x 60 seconds2,400 seconds, 40 minutes40 minutes
Conservative12 x 300 seconds3,600 seconds, 60 minutes60 minutes
Computed by script from the multipliers and poll intervals in the Cisco mode table. The results match the printed windows. The chapter's text also contains the phrase that the default time is 120 seconds, next to a default multiplier of 120 for the aggressive mode, and the pages read do not reconcile them. The arithmetic here treats 120 as the multiplier, which is the reading that matches the 20 minute window.

Release gating and mixed versions

EAAR is a newer feature, so the first questions on a real network are about releases and neighbors. It is listed from IOS XE Catalyst SD-WAN Release 17.12.1a with Manager Release 20.12.1, and the rule for mixed pairs is simple: a tunnel uses the enhanced measurement only when both ends are able and enabled. Everything else falls back to the classic measurement, silently, so a partial rollout can look fine in the policy and still react at the old speed.

Diagram
A rollout that avoids silent fallback
A rollout that avoids silent fallback

Upgrade both ends to a release that supports EAAR. Enable it on both ends. Verify the measurement mode per tunnel. Then tune the mode.

  1. Upgradeboth ends to asupported release
  2. Enableon both ends,off by default
  3. Verifymeasurement modeper tunnel
  4. Tunepick a mode,then test
Order follows the interoperability notes in the Cisco chapter.
Diagram
Which measurement a tunnel uses
Which measurement a tunnel uses

When both ends run a supported release and EAAR is enabled on both, the tunnel uses enhanced measurement. When either end is older or has EAAR disabled, the tunnel uses BFD-based measurement.

Both ends readysupported releaseEAAR on at both ends
Either end not readyolder release orEAAR still off
Per tunnel, decided by both ends.
Diagram
Feature history rows in the application-aware routing chapter
Feature history rows in the application-aware routing chapter
CapabilityIOS XE Catalyst SD-WAN releaseManager release
Application-aware routing policy support for multicast17.3.1a20.3.1
Support for six SLA classes per policy17.3.1a20.3.1
Per-class application-aware routing17.4.1a20.4.1
SLA class support enhancement (up to 16 SLA classes)17.6.1a20.6.1
Application-aware routing and data policy SLA preferred colors17.6.1a20.6.1
Enhanced application-aware routing (from its own chapter)17.12.1a and later20.12.1 and later
Rows copied from the feature history tables of the Cisco Catalyst SD-WAN Policies Configuration Guide, IOS XE Catalyst SD-WAN Release 17.x, application-aware routing chapter and its enhanced application-aware routing chapter, both updated December 2025; the older rows are listed for Cisco vManage releases. The application-aware routing chapter was read only in part, so other rows, such as fallback to best path and IPv6 support, exist but their releases were not confirmed here. The release notes were not read.
Diagram
Restrictions and guidelines in the Cisco chapter
Restrictions and guidelines in the Cisco chapter
TopicWhat the chapter saysReading
Branch devices with loopback unbind modeListed as not supportedA site that uses this mode stays on the classic measurement or needs another design
GRE tunnelsNo per-queue measurementPer-class loss on a GRE tunnel is not available
Tunnel and interface typesIPsec and GRE; all TLOC and WAN interface types; TLOC extension; IPv4 and IPv6 underlay (summarised)No interface type needs to be avoided, apart from the restriction above
Minimum intervalSLA update and switchover at a minimum of 10 seconds (summarised)Faster than 10 seconds is not on offer
Supported devicesCisco IOS XE Catalyst SD-WAN devicesOther platform types were not covered in the page read; check before assuming support
From the enhanced application-aware routing chapter, updated December 2025. Rows marked summarised come from a summary of the chapter and not from the verbatim text, so confirm them in the chapter for the release in use.

Enabling and checking EAAR

The commands in the chapter sit under the bfd keyword. Enabling is one command, and the poll interval, the multiplier and dampening have their own. The checks are a parameter view, a per-tunnel summary and the session list, where the chapter says an EAAR flag appears. The point of checking is to see which measurement each tunnel uses, because a fallback to the classic measurement does not raise an alarm.

Diagram
Commands printed in the chapter
Commands printed in the chapter
PurposeCommand as printedNote
Switch EAAR onbfd enhanced-app-route enableDisabled by default
Set the poll intervalbfd enhanced-app-route pfr-poll-intervalThe chapter shows no value or range in the part read
Set the multiplierbfd enhanced-app-route pfr-multiplier <number>Defaults of 10 seconds and 6 when EAAR is on (summarised)
Ignore local queue lossbfd enhanced-app-route ignore-local-lossBy default both local and WAN loss are counted (summarised)
Switch dampening on and set its multiplierbfd sla-dampening enable and bfd sla-dampening multiplier <number>Mode values are in the table earlier in this lesson
Show the parameters in useshow sdwan app-route paramsShows the EAAR, classic and dampening settings
Show the session list with an EAAR flagshow sdwan bfd sessions altThe flag appears in the FLAGS column
Show the per-tunnel summaryshow sdwan app-route stats summaryLists enhanced-app-route and sla-dampening-index per tunnel
Command lines from the enhanced application-aware routing chapter for IOS XE Catalyst SD-WAN Release 17.x, updated December 2025. Syntax and availability vary by release, platform and mode, so confirm with command help on the device in use.
Example output written for this lesson, simplified; real output has more fields and a different layout
BR-01#show sdwan app-route params
Enhanced Application-Aware routing
  Config:            Enabled
  Poll interval:     10000
  Poll multiplier:   6
App route
  Poll interval:     600000
  Poll multiplier:   6
SLA dampening
  Config:            Enabled
  Multiplier:        120
The enhanced values match the aggressive mode and the classic values match the defaults. Units are not printed in the sample this layout follows. If they are milliseconds, 10000 is 10 seconds and 600000 is 10 minutes, which agree with the Cisco defaults, but that is an assumption to confirm on the release in use. The layout and the values are written for the example.
Example output written for this lesson, simplified; real output has more fields and a different layout
BR-01#show sdwan app-route stats summary
remote-system-ip  local-color   remote-color  enhanced-app-route  sla-dampening-index
10.255.1.1        mpls          mpls          Enabled             0
10.255.1.2        biz-internet  biz-internet  Enabled             0
10.255.2.2        biz-internet  biz-internet  Disabled            0
The first two tunnels, to the hubs, use the enhanced measurement. The third, to BR-02, does not, which is the silent-fallback case: both ends have to be enabled before that tunnel reacts at the enhanced speed. The field names are the ones the chapter lists for this command. The layout, the colors and the values are invented for the example.
Diagram
Where to look when a tunnel reacts slowly
Where to look when a tunnel reacts slowly

Check the release at both ends, check that EAAR is enabled at both ends, check the parameters in use, and check the tunnel in the summary.

  1. Release at both ends17.12.1a or lateron each device
  2. EAAR enabledon both ends,off by default
  3. Parametersshow app-routeparams
  4. The tunnelflag and summaryline for that tunnel
Cheapest evidence first.

Choosing a mode

The right mode depends on how costly a bad minute is and how noisy the transport is. Voice over a transport that sours briefly and recovers favors a short window. A bulk transfer over a transport with frequent brief dips favors a long one, because moving a flow has a cost of its own. The table is advice for planning a test, not a Cisco recommendation, and the answer for a real network comes from a trial that measures how often traffic moves.

Diagram
Three situations, three starting points
Three situations, three starting points

A voice flow on a transport that degrades and recovers suits the aggressive mode. A mixed workload suits the moderate mode. A noisy transport with bulk traffic suits the conservative mode.

Starting mode
  • Voice sours faststart withaggressive
  • Mixed workloadstart withmoderate
  • Noisy and bulkstart withconservative
Starting points for a trial, not rules.
Diagram
Which mode to try first (study advice)
Which mode to try first (study advice)
SituationMode to try firstWhat to watch during the trial
Voice and video on a transport that degrades briefly and recoversAggressiveHow often flows move and return, and whether users notice the moves
A mix of business applications on two reasonable transportsModerateTime to leave a degraded tunnel, compared with the class limit
Bulk traffic on a noisy transport that dips oftenConservativeWhether the dips are real faults or short bursts that need no move
A site where the remote end is not yet upgradedNone until both ends are readyThe measurement flag per tunnel, because the tunnel stays classic
Study advice based on the facts above, not a Cisco recommendation. The three modes are the ones in the Cisco chapter, and custom values need a CLI template.

Learn more: Brownout and Fallback BehaviourSLA Classes and Policy ThresholdsBFD Timing, Aggregation and Measurement LimitationsFEC and Packet Duplication

Test yourself

Predict · scenario 1

How does EAAR measure path quality compared with classic application-aware routing?

Predict · scenario 2

From which release is EAAR listed in the Cisco chapter?

Predict · scenario 3

The local edge runs EAAR, and the remote edge runs an earlier release. What does that tunnel use?

Predict · scenario 4

What are the default EAAR poll interval and multiplier when the feature is enabled, according to the chapter summary?

Predict · scenario 5

In the simple model with a 2 percent limit and a steady 10 percent loss, how long does the aggressive mode (10 seconds, multiplier 6) take to push the average over the limit?

Predict · scenario 6

What is the dampening window in the aggressive mode, from the multiplier of 120 and the 10 second poll interval?

Predict · scenario 7

Which restriction does the Cisco chapter list for EAAR?

Predict · scenario 8

Which statement about the three modes matches the Cisco table?

FAQ

Is EAAR switched on by default?
No. The Cisco chapter says it is disabled by default and a community note makes the same point. It is enabled with a command or template setting, and it has to be enabled on both ends of a tunnel to take effect.
What happens when only one end supports EAAR?
The tunnel falls back to the classic BFD-based measurements. The Cisco chapter describes this for a remote device that has not been upgraded to 17.12.1a, and for two upgraded devices where EAAR is not enabled.
Does EAAR replace BFD?
Not according to the notes read. The Cisco commands sit under the bfd keyword, and a community note says BFD is still used to report the measurements. Tunnel liveness stays a BFD job, so the two features work together.
Can the timers be set to any value?
The Cisco chapter gives three modes, aggressive, moderate and conservative, and says the values are changed only with a CLI template. A community note advises against a poll interval below 10 seconds, and the chapter lists 10 seconds as the minimum interval for an SLA update.
Does a faster decision make a bad path better?
No. EAAR changes how soon traffic leaves a tunnel that misses its class. It cannot create a good path when every tunnel is poor, and a short window can make a noisy path flap, so the dampening setting that the chapter pairs with each mode deserves a lab test.