The probe is a sample, not the traffic
Application-aware routing decides from numbers that BFD measures inside each tunnel. Those numbers are only as good as the probe. A BFD probe is one small packet that travels the same tunnel as user traffic, but it is not user traffic. It has its own size, its own rate and its own marking, and the network between the two edges can treat it differently from a voice packet or a file transfer.
A BFD probe is small, regular and marked for control traffic. A user packet can be large, bursty and marked for voice or data. The two share the tunnel but can be queued, policed or dropped differently along the path.
| Property | Probe | Why it can differ from user traffic |
|---|---|---|
| Size | Small | A fault that drops only large packets is invisible |
| Rate | One per interval | A cap that only bites at a higher rate is invisible |
| Marking | Its own | A provider queue for another class can be congested or capped alone |
| Timing | Regular | Bursts between probes are averaged away |
| Direction | Round trip | Delay that differs in each direction is combined into one figure |
How fine can the measurement be
Loss is counted in whole probes. In a measurement interval the edge sends a fixed number of probes, and one lost probe moves the loss figure by one divided by that number. A limit that is smaller than that step cannot be measured, however it is written in the SLA class.
| Poll interval | Probes in it | Each lost probe adds | Over five intervals |
|---|---|---|---|
| 60 seconds | 60 | 1.67 % | 0.33 % |
| 120 seconds | 120 | 0.83 % | 0.17 % |
| 600 seconds | 600 | 0.17 % | 0.03 % |
The edge sends a fixed number of probes in each interval, counts how many were answered, converts the missing ones to a percentage, and averages the last few intervals into the figure that is compared with the SLA class.
- Senda fixed numberof probes
- Countanswered andmissing
- Percentmissing dividedby sent
- Averagelast fewintervals
The step size matters most when an SLA limit is set. A limit is crossed only when enough whole probes are lost in one interval, and a small limit needs just one.
| SLA loss limit | 60 probes in the interval | 120 probes in the interval | 600 probes in the interval |
|---|---|---|---|
| 0.1 percent limit | 1 probe (1.67 %) | 1 probe (0.83 %) | 1 probe (0.17 %) |
| 1 percent limit | 1 probe (1.67 %) | 2 probes (1.67 %) | 7 probes (1.17 %) |
| 2 percent limit | 2 probes (3.33 %) | 3 probes (2.50 %) | 13 probes (2.17 %) |
| 5 percent limit | 4 probes (6.67 %) | 7 probes (5.83 %) | 31 probes (5.17 %) |
The same limit applies to delay and jitter, which are computed from few samples per interval. They are good for telling a tunnel that is 40 milliseconds apart from one that is 120 milliseconds apart. They are not a precise instrument for differences of a millisecond or two, so an SLA limit should leave room for noise.
Hello interval, multiplier and the cost of speed
Liveness uses the hello interval and the multiplier: a tunnel is declared down when no probe is answered for the interval multiplied by the multiplier. Shorter values detect a dead tunnel sooner, and they also send more packets and tolerate less jitter on the path. Because a hub carries a session for every tunnel from every branch, the packet load grows with the number of branches as well as with the interval.
| Hello interval | Multiplier | Detects a dead tunnel in |
|---|---|---|
| 1,000 ms | 7 | 7.0 seconds |
| 1,000 ms | 3 | 3.0 seconds |
| 300 ms | 6 | 1.8 seconds |
| 5,000 ms | 7 | 35 seconds |
| Hello interval | Probes per second in each direction | Compared with one second |
|---|---|---|
| 1,000 ms | 1,000 | Same |
| 500 ms | 2,000 | 2 times |
| 200 ms | 5,000 | 5 times |
Faster timers detect a dead tunnel sooner. They also raise the packet and processing load, make short provider hiccups look like failures, and consume more of the hub's session capacity.
- Soonerdead tunnelfound quickly
- More loadprobes andprocessing
- More flapsshort glitcheslook like faults
- Less scalefewer sessionsper hub
A worked case: clean probes and bad calls
Users at BR-02 report choppy calls every morning between 09:00 and 10:00. The SLA dashboard for the mpls tunnel to HUB-01 shows no violations. Priya reads what the edge measures.
BR-02#show sdwan app-route stats TUNNEL (remote) LOSS LATENCY JITTER mpls to HUB-01 mpls 0 46 7 biz-internet to HUB-01 biz-inet 1 62 12
Next she checks something that does not depend on the probes: the call quality report from the voice system, and the provider's report for the voice class on that circuit.
| Source | What it shows |
|---|---|
| BFD probes, mpls | 0 % loss, 46 ms, 7 ms |
| Call quality report | 25 simultaneous calls, about 26 % reported packet loss |
| Provider voice class | Contract 2.0 Mbps, offered 2.7 Mbps, about 0.7 Mbps dropped |
The probes report no loss on the mpls tunnel. The call quality report shows about a quarter of voice packets lost during the morning peak. The provider's voice class is capped at 2 megabits and the site offers 2.7 megabits at peak. The probes use a different class and are not dropped, so the SLA numbers stay clean while voice is damaged.
- Probesmpls: 0 % loss, 46 ms, 7 msThe tunnel looks healthy
- UsersAbout 26 % voice loss at 25 callsChoppy calls every morning
- ProviderVoice class capped at 2.0 MbpsOffered 2.7 Mbps, 0.7 Mbps dropped
- FixRaise the voice rate or move calls off mplsAdd independent monitoring
The repair is outside the SD-WAN policy. The contracted voice rate has to cover the busiest hour, so Priya asks the provider to raise it to 3.5 Mbps and the network team checks at the next morning peak that the reported loss has fallen. She also adds the call quality report to the weekly review next to the SLA dashboard, because the dashboard only reports what the probes can see.
| Symptom | First check | Likely cause |
|---|---|---|
| Bad calls, clean SLA numbers | Independent call quality and provider class counters | A cap or queue that the probes do not cross |
| A tunnel flaps often with short timers | Detect time against the typical path jitter | Timers tighter than the path can hold |
| SLA limit does not trigger on small loss | Probes per interval against the limit | A limit finer than one probe |
| Hub CPU or session limit reached | Number of sessions and hello interval | Timers shortened across many sessions |
Learn more: BFD-derived Loss, Latency and JitterSLA Classes and Policy ThresholdsSD-WAN QoS Concepts
Test yourself
The probes on a tunnel show 0 percent loss, but voice sounds choppy and the call quality report shows about 26 percent packet loss. Which explanation fits best?
With one probe a second and a 120 second poll interval, what does one lost probe add to the loss figure for that interval?
An SLA class has a loss limit of 0.1 percent. The poll interval holds 120 probes. What is the problem?
A hub has 1,000 BFD sessions and the hello interval is shortened from 1,000 ms to 200 ms. What happens to the probe rate in each direction?
What is the most reliable way to check whether the probe numbers represent what voice users experience on a transport?
An SLA class has a loss limit of 2 percent and acts when loss is above the limit. The poll interval holds 120 probes. How many lost probes in one interval push the figure past the limit?
A branch tunnel flaps several times a day after the hello interval was cut from 1,000 ms with a multiplier of 7 to 300 ms with a multiplier of 3. The provider has short hiccups of about one second. What explains the flaps?
Priya compares the probe figures for a tunnel with the call quality report. Both show about 3 percent loss in the same hour. What does that tell her?