Unit 7: IPsec and BFD·Lesson 7.2 (2 of 5 in this unit)·43 of 62 in the Cisco SD-WAN course
BFD roles, sessions and telemetry
BFD as failure detection and path measurement in each tunnel, the timers and detection time, and how to read the session list.
Intermediate · 8 min read
You'll learn to explain the two jobs of BFD in SD-WAN, calculate detection time from the timers, and read a BFD session list.
Technical definition
BFD in SD-WAN is a lightweight hello protocol that runs inside every data tunnel between two TLOCs. A tunnel is considered usable only while its BFD session is up. The same exchange also gives loss, latency and jitter measurements for each path.
Two jobs
Diagram
What BFD does
Detection and measurement.
DetectDeclares the tunnel downwhen hellos stop
and
MeasureLoss, latency, jitterper path
One exchange serves both.
Timers
Diagram
BFD timers
Setting
Meaning
Common default
Hello interval
Time between hellos
1 second
Multiplier
Missed hellos before the session is declared down
7
Detection time
Interval multiplied by multiplier
About 7 seconds
Path measurement interval
How often loss, latency and jitter are summarised for policy
Longer, set separately
Defaults can differ by release. They are set per colour, so MPLS and internet links can use different values.
Diagram
Failure detection
Hellos stop and the session drops.
1Hellosstop arriving
2Multiplierreached
3Sessiongoes down
4Trafficmoves to another path
Routes through that tunnel are then withdrawn.
Example output written for this lesson, simplified; real output has more fields and a different layout
BR-01#show sdwan bfd sessions
SYSTEM IP SITE STATE SOURCE TLOC REMOTE TLOC DETECT MULT TX INTERVAL
10.255.1.1 100 up mpls mpls 7 1000
10.255.1.1 100 up biz-internet biz-internet 7 1000
BR-01 has two sessions to HUB-01, one per transport, both up with the default timer values. A session that flaps between up and down points to loss on that path. The columns are illustrative.
Read the state first: up, down, or flapping.
If a session is down but the TLOC is present, check reachability, NAT, firewall and IPsec.
Tuning timers is a trade-off; test in a lab before changing production values.
BFD hello is 1 second and the multiplier is 7. About how long until a failure is declared?
Predict · scenario 2
Which two jobs does BFD do in SD-WAN?
FAQ
What is the detection time?
The hello interval multiplied by the multiplier. With a one-second interval and a multiplier of seven, a failure is declared after about seven seconds. Lowering the values detects failures sooner and raises the risk of false alarms on noisy links.
Is BFD sent to the Controller?
No. BFD runs between WAN Edges, through the data tunnels. Controller connections have their own keepalives.
Why does application-aware routing depend on BFD?
The loss, latency and jitter it compares with a service-level agreement are measured from the BFD exchange, so its accuracy depends on the BFD settings.